Shanxi Tobacco Company Changzhi City Company Selects Engineering Cost Consultation Unit Tender Notice

Under the entrustment of the Shanxi Tobacco Company Changzhi City Company, the Shanxi Provincial Tobacco Company Changzhi City Company selected the construction cost consulting unit for public bidding. The relevant matters are now announced as follows:

1. Project overview and scope of tender
1.1 Project Name: Shanxi Tobacco Company Changzhi City Company Select Project Cost Consulting Unit
1.2 Project Number: SXGDFW201711-10
1.3 Bidding content: providing cost consulting services for repair projects of the following two million yuan system
1.4 Funding Sources: Self-funding
1.5 Project Location: The county's system-level county-level bureau (Marketing Department)
2. Bidder qualification requirements
2.1 The bidder must have an independent legal person qualification and a valid business license in the territory of the People's Republic of China; it must not be ordered to suspend business, property must be taken over, frozen, or bankrupted.
2.2 The bidder’s legal representative shall be the same person or different bidders with controlling and management relationships, and may not participate in the bidding for this project at the same time.
2.3 The bidder shall have the qualifications for the project cost consultation Grade B and above issued by the construction administrative department.
2.4 Proposed project managers must have: a certificate of cost engineer registration issued by the construction administrative department and should be registered with the bidder unit, and have experience in cost consulting management of public building projects.
2.5 The Commonwealth does not accept bids for this consortium.
3. Obtaining tender documents:
3.1 Invite the bidder from December 13, 2017 to December 19, 2017 (9:00 am to 6:00 pm, Beijing time).
3.2 The bidding documents are priced at RMB 500 each, paid in cash and will not be refunded after sale.

Power Meter 2 Rates

Power Meter is a monitoring and testing instrument which determines the power consumption of a connected appliance and the cost of the electricity consumed.

Installing the batteries

Install 3.6V rechargeable Battcrics(NI-MH) . The purpose of the batteries is to store the total electricity and mcinory setting.

Resetting

If an abnormal display appears or the buttons produce no response, the instrument must be reset. To do this,press the RESET button.

Display Mode

Entire LCD can be displayed for about 1 minute and then it automatically gets into Model. To transfer from one mode to the other, press the FUNCTION button.

Mode 1: Time/Watt/Cost Display Display duration(how long) this device connect to power source.LCD on first line shows 0:00 with first two figures mean minutcs (2 figures will occur while occur at 10 min) and the rest shows seconds. After 60mins, it displays 0:00 again with first two numbers meas hour(2 figures will occur at 10hours) and the rest shows minutes. The rest can be done in the same manner which means after 24 hours, it will rc-caculatc. LCD on second line displays current power which ranges in 0.0W~9999W. LCD on third line displays the current electricity costs which ranges in 0.0cost~9999cost. It will keep on O.OOcost before setting rate without other figures.

Mode 2: l ime/Cumulative electrical quantity Display Display duration(how long) this device connect to power source.

LCD on first line shows 0:00 with first two figures mean minutes(2 figures will occur while occur at 10 min) and the rest shows seconds. After 60mins, it displays 0:0() again with first two numbers meas hour(2 figures will occur at 10hours)and the rest shows minutes. The rest can be done in the same manner which means after 24 hours, it will re-caculate. LCD on second line displays current cumulative electrical quantity which ranges in 0.000K WH 〜 9999KWII without other figures. LCD on third line displays''DAY''- "1 "will be showed on numerical part(thc other three figures will be showed at carry) which means it has cumulated electrical quantity for 24hours(one day). The rest can be done in the same manner untial the maximal cumulative time of 9999 days.

Mode 3: Time/Voltage/Frequency Display LCD on first line displays the same as Mode 1 dones. LCD on second line displays current voltage supply (v) which ranges in 0.0V~9999V .LCD on third line displays current frequency (HZ) which ranges in 0.0HZ~9999HZ without other figures.

Mode 4: Time/Current/Power Factor Display LCD on first line displays the same as Mode 1 dones.

LCD on second line displays load current which ranges in 0.0000A~9999A. LCD on third line displays current power factor which ranges in 0.00PF 〜 1 .OOPF without other figures.

Mode 5:Time/Minimum Power Display LCD on first line displays the same as Mode 1 clones. LCD on second line displays the miniinum power which ranges in 0.0W~9999W. LCD on third line displays character of "Lo" without other figures.

Mode 6: I,ime/Maximal Power Display LCD on first line displays the same as Mode 1 dones. LCD on second line displays the maximal power which ranges in 0.0W~9999W. LCD on third line displays character of "Hi" without other figures.

Mode 7: Time/Price Display LCD on first line displays the same as Mode 1 dones. LCD on third line displays the cost which ranges in O.OOCOST/KWH 〜 99.99COST/KWH without other figures.
Overload Display: When the power socket connects the load over 3680W, LCD on second line displays the"O VER LOAD" with booming noise to warn the users,( 60470643, 60469303,selectable choice)
Supplemental informations:
1: Except tt OVERLOAD , ' interface, LCD on first line display time in repitition within 24hours.
2: LCD on first line, second line or third line described in this intruction take section according to two black lines on LCD screen. Here it added fbr clarified purpose.
3. Mode 7 will directly occur while press down button "cost".
4. [UP"&''Down" are in no function under un-setting mode.
Backlight Mode:
Connect to AC power,backlight im mediately light,if not press any button,backlight will went off in 15 seconds.
When press any of the buttonsbacklight start light again. (Backlight only light when it connect to AC power,backlight cannot light if use battery)
Setting Mode
1. Electricity price setting
After keeping COST button pressed lasting more than 3 seconds(LCD on third line display system defaults price, eg O.OOCOST/KWH ),the rendered content begins moving up and down which means that the device has entered the setting mode. Then press FUNCTION button to change selection and press UP/DOWN to set what you want. (On pressing once, the figure after domical point will increase or decrease accordingly. On pressing and hold-on, figures after demical point will increase or decrease slowly in 2 seconds while figures change quickly when hold-on time exceeds 2 seconds. When hold-on time reaches 10 seconds or more, the figures after demical point will stop while the figures before demical point begin to increasing or decreasing.) After that, press FUNCTION fbr swithing, then press [UP'nd "DOWN" button again to set value which ranges in OO.OOCOST/KWH 〜 99.99COST/KWH. After setting all above, press COST to return to Mode7 or it will automatically return to Mode7 without any pressing after setting with data storage.

Power meter double rates, power meter two rates, cost rate socket, power meter cost rate, energy meter cost rate, cost socket, cost plug

NINGBO COWELL ELECTRONICS & TECHNOLOGY CO., LTD , https://www.cowellsocket.com