Noise countermeasures for LED bulbs (top) There are two modes for noise current

The revised Japanese Electrical Appliances Safety Law will be implemented from July 2012. After this revision, LED bulbs have also become the object of this regulation. Of the several limiting criteria, particular attention is paid to the limits of electromagnetic noise intensity. At present, there are LED lighting fixtures on the market that have higher electromagnetic noise than incandescent bulbs and bulb-type fluorescent lamps. With the implementation of the revised "Electrical Supplies Safety Law", strict noise countermeasures must be taken. This article will analyze the noise types, evaluation methods and countermeasures of LED lighting according to the current status of LED lighting.
The lack of power supply originating from the Great East Japan Earthquake caused people's awareness of power saving to rise rapidly. Energy-saving products such as LED lighting fixtures and LCD TVs using LED backlights are gradually becoming the mainstream in the market. In terms of LED lighting equipment, bulb type, fluorescent tube type, chandelier and ceiling lamp have already been put on the market.
Among them, LED bulbs are not only well-known lighting manufacturers, but also new products from manufacturers have begun to sell at low prices in household goods stores. The LED bulb market is rapidly expanding.
At the same time, the environment for the popularization of LED bulbs, such as standardization and regulatory introduction, is also being established. Previously, LED bulbs were not covered by the Electrical Appliances Safety Law. Therefore, some LED lighting products have large electromagnetic noise. In this way, if the lamp of the street lamp is replaced by a mercury lamp into an LED bulb, it will cause obstacles to reception of the television and the radio.
An incandescent light bulb is a resistive load with no internal power supply circuitry, so there is no such electromagnetic noise problem. But after switching to LED bulbs, the problem is highlighted. If we promote the popularity of LED lighting in this way, there will be multiple sources of noise in the home.
Therefore, overseas, LED lighting fixtures, like ordinary lighting fixtures, must comply with the international standard CISPR15 ("Limitations and Measurement Methods for Radio Disturbance Characteristics of Electrical Lighting and Similar Equipment"), and all countries have introduced restrictions based on this standard.
Japan will also begin to implement such restrictions. Starting from July 2012, LED bulbs will become the object of application of the Electrical Appliances Safety Law. It also includes a specification regarding the noise intensity (the frequency band of the predetermined noise terminal voltage is 526.5 kHz to 30 MHz, and the frequency band of the noise power is 30 MHz to 300 MHz).
Regardless of whether the Electrical Appliances Safety Law is implemented or not, as the LED lighting market expands, the problem of interference with other electronic products is unavoidable.
The electromagnetic noise source of an LED bulb is its power supply circuit. Since the power supply portion of the LED bulb is more restrictive in terms of size, it is necessary to implement electromagnetic noise countermeasures with a minimum of components. Of particular importance is the choice of noise countermeasure components. Therefore, this paper will focus on the types of electromagnetic noise leaked by LED lighting power supply circuits and their measurement methods, as well as the component selection methods that can effectively suppress electromagnetic noise.
There are two modes of noise current
In general, EMC (electromagnetic compatibility) standards define two types of electromagnetic noise measurements, namely "radiation noise" radiated into the air and "conducted noise (noise terminal voltage) flowing through the power line). "(figure 1). There are both noise components in the "difference mode" and "common mode" modes in the noise current. Differential mode noise is the noise generated between the signal line and the ground line. The common mode noise is the noise generated between the earth and the signal line and the earth and ground. The signal line and the ground line have the same type of noise as the ground, that is, have the same phase and the same amplitude.
Figure 1: Example of electromagnetic noise observed in an LED bulb
The EMC regulations define the measurement of two types of electromagnetic noise, radiated noise and conducted noise. LED bulbs are no exception. Some LED bulb products have noise that exceeds the CISPR15 specification (quasi-peak: QP and average: AV).
The main component of radiated noise is common mode noise (Fig. 2(a)). This is because the current loop area of ​​the noise is much larger than the current loop area of ​​the differential mode noise.
Figure 2: There are two modes of electromagnetic noise
Electromagnetic noise has two modes: differential mode and common mode. The main part of radiated noise is the common mode component (a). In the conducted noise, the differential mode and the common mode are mixed and transmitted. (b)
The differential mode and the common mode component can be observed in the conducted noise (Fig. 2(b)). If it is conducted noise, it is necessary to take countermeasures based on the characteristics of the noise components. Let me first introduce the method of suppressing conducted noise.
Distinguish the noise pattern of the power supply
Conducted noise measurement, generally using a V-type artificial power network, for the respective electromagnetic noise of power line 1 (L1) and power line 2 (L2), measuring the quasi-peak * (QP value) and the average value (AV value, Figure 3 ( a)). Although the V-type artificial power network can measure the noise voltage between each power line and the earth, but because of the combination of differential mode noise and common mode noise, it is unclear which noise mode is the main body.
Figure 3: Measurement using a V-type and Δ-type artificial power network

 Wireless Ir Door Sensor

Wireless Ir Door Sensor also can called Cabinet Door Light Switch. The wireless smart driver connect the control box directy, then we can use wireless IR door sensor to control the light. Their communication is by 2.4G.

Description of Wireless IR Door Sensor

Replaceble blaatery operate

IR with 3 years standby

PIR/Touch with 10 years standby

More than 10000 times operate

Wireless switch

Easy for installation

 IR Door

FAQ:

Q1. How do you ship the goods and how long does it take to arrive?
A: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline  and sea shipping also optional.

Q2. How to proceed an order for led light?


A: Firstly let us know your requirements or application.
Secondly We quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.

Q3. Is it OK to print my logo on led light product?


A: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.

Q4: Do you offer guarantee for the products?


A: Yes, we offer 2-5 years warranty to our products.


 

Wireless Ir Door Sensor

Wireless Ir Door Sensor,Cabinet Door Light Switch,Door Light Switch,Led Cabinet Light Door Switch

Shenzhen Jedver Smart Lighting Co., Ltd. , https://www.jederwell.com